System Modular, analytical system, consolidated work area for Clinical Chemistry and Immunology, expandable and re-configurable on site
Test throughput 170 up to more than 10,000 tests/hr
800 up to more than 10,000 tests/hr with photometric modules
170 to 680 tests/hr with E 170 modules
800 up to more than 6000 tests/hr with photometric and E 170 modules
Type of modules ISE 900 and ISE 1800 module: Electrolyte measuring unit
D 2400 module: Photometric measuring unit
P 800 module: Photometric measuring unit
E 170 module: ECL technology measuring unit
Number of module combinations More than 30 module cormbinations
Up to 18 combinations with photometric modules
Up to 4 combinations with E 170 modules
Up to 16 combinations with photometric and E 170 modules
Number of channels (reagent slots) 25 up to more than 100 channels/reagent slots:
3 channels on ISE modules
16 channels on D 2400 module
22 to 44 channels (reagent slots) on P 800 module
25 channels (reagent slots) on E 170 module
Programmable parameters 160 with photometric and E 170 modules
86 photometric tests, 3 ISE tests, 8 formulas, 3 serum indizes with photometric modules
60 heterogeneous tests with E 170 modules
Sample input/output on Core Unit
Load/unload capacity: 300 samples/60 racks on 2 trays
Rack: 5 Position, RD standard
Rack types: Routine, STAT, Control, Calibrator, wash, rerun (manual)
Tray: tray with 30 racks/150 samples, RD standard
STAT port: STAT samples are processed with first priority
Sample types Serum, Plasma, Urine, CSF, others
Sample container types
Primary tubes: 5 to 10 ml, 16 x 100, 16 x 75, 13 x 100, 13 x 75 mm
Sample cup: 2.5 ml
Micro cup: 1.5 ml (not on D 2400 and E 170 modules)
Cups on tube: cup on 16 x 75 mm tube
Sample volume 2 to 50 μl per test
Sample bar codes Code 128; Codabar (NW7); Interleaved 2 of 5; Code 39
System interfaces RS 232 serial interface, bi-directional
Interface to the Service Processor and modem for Remote Diagnostics Access
Rerun/reflex function Automatic rerun and manual rerun
Automatic reflex is supported by the system,
reflex request to be provided by a Data Manager or LIS
Electrical requirements
Power requirements: 230/400 Volts AC 3/N/PE
or 110 Volts AC
4 to 12 KVA
Frequency: 50 Hz or 60 Hz +/– 0.5 %
Regulatory requirements GS, FTZ, CE, UL, CUL
Physical dimensions
Width: 285 to 885 cm
Core unit with ISE module: 165 cm
D, P, E module: 120 cm
Depth: 110 cm; D, P, E module: 80 cm
Height: 120 cm w/o D module, 165 cm
  with D module
Control unit: width: 120 cm, depth: 80 cm,
  height: adjustable
Weight
750 to 2850 kg  
Core Unit with ISE module: approx. 450 kg
ISE 1800 module: approx. plus 30 kg, included in the Core Unit
D 2400 mdule: approx. 450 kg
P 800 module: approx. 300 kg
E 170 module: approx. 300 kg
Control unit:
approx. 75 kg
   
 